UOP 1000
Original price was: $240.00.$144.00Current price is: $144.00.
Smoke Point Determination of Kerosene and Aviation Turbine Fuel Using an Automated Method
Published by | Publication Date | Number of Pages |
UOP | 03/01/2013 | 6 |
UOP 1000 – Smoke Point Determination of Kerosene and Aviation Turbine Fuel Using an Automated Method
This method is for determining the smoke point of kerosene and aviation turbine fuel utilizing an automated instrument with a camera capable of digitalizing the flame image. Smoke point is defined as the maximum height, in millimeters, of a smokeless flame of fuel burned in a wick-fed lamp of specified design. In general, higher aromatic concentration of a fuel will produce a shorter flame height, while low aromatic concentration will produce a higher flame height with lower smokeproducing tendency. The automated method demonstrates improved precision and removes analyst subjectivity of visually observing flame height by manual smoke point methods.
Product Details
- Published:
- 03/01/2013
- Number of Pages:
- 6
- File Size:
- 1 file , 81 KB
- Redline File Size:
- 2 files , 2.3 MB